SPECIFICATIONS
Environmental
Operating temperature: 0°C to +60°C
Storage temperature: –40°C to +85°C
Relative humidity: 10 to 95%, non-condensing
Regulatory Compliance
CE Mark
CFR 47, Part 15 Class A
Functional
Compliance: ANSI/ATA 878.1
Hub delay: 300 ns max @ 2.5 Mbps
Unlatch delay time: 5.9 µs max @ 2.5 Mbps
LED Indicators: ACTIVITY green
AC
Input voltage: 8–24 Volts
Input power: 6 VA
Input frequency: 47–63 Hz
INSTALLATION
The QL was designed as a desktop unit and should be installed on a stable
surface in a horizontal plane. Four rubber feet protect the mounting surface.
Power is derived from a nominal 24 VAC source, either a local power
supply or the wall-mounted transformer provided with the QL. This trans-
former is normally for a 120 VAC mains, but (-E) models are supplied with
a 230 VAC transformer.
TD990300-0IH
2
Power Requirements
Mechanical